Solutions

Units and Configurations

Standard modular units in four lengths, deployed individually, linked or stacked, and fitted out to the requirements of each project.

A modular system, configured to your requirement

Every facility is assembled from standard, factory-built modules. Configuration, layout and fit-out are determined by use, occupancy and site constraints, allowing the same system to deliver a single welfare point or a multi-storey office complex.

Which configuration do I need?

A starting point by requirement. The final configuration is confirmed at specification stage.

RequirementTypical configuration
Gatehouse, storage or compact officeSingle 10ft or 16ft unit
Site office for up to fourSingle 20ft unit
Open-plan office for up to eightTwo-bay office (two 20ft modules)
Offices, meeting rooms and welfareLinked office complex
Larger workforce on a small footprintStacked welfare facility
Temporary living for a householdTwo-bay living unit (two 20ft modules)
Configuration

Two-bay office

Two 20ft modules linked side by side to form a single open-plan office of approximately 6.1m x 4.9m.

Cutaway layout of a two-bay modular office with workstations

Suited to

Project teams • Temporary head offices • Sales offices

Configuration

Linked office complex

Multiple modules linked by an internal corridor to create a self-contained office building.

Cutaway layout of a linked modular office complex with private offices and meeting room
Configuration

Stacked welfare facility

Four or six modules stacked and linked to serve a larger workforce on a constrained footprint.

Two-storey modular building on a yard
Configuration

Single unit

A single module delivered, levelled and connected, with fit-out kept to the essentials.

Single modular unit installed beside an industrial building
Configuration

Two-bay living unit

Two 20ft modules linked side by side, approximately 6.1m x 4.9m, partitioned and fitted out as temporary living accommodation. There is no standard layout: rooms, insulation and services are specified for each project.

Residential use may need planning permission, which is the client’s responsibility. As the fit-out is specific to each layout, purchase is usually better value than hire. Larger modules and higher-insulation ranges, such as CONTAINEX PLUS Line, can be proposed for comparison.

Double bedroom Showerand WC Single Kitchen and living area approx. 6.1m approx. 4.9m Indicative layout. Final layout agreed at design stage.

Suited to

Self-build projects • Accommodation during major renovation • Staff accommodation

Unit dimensions

Modules are available in four standard lengths and three heights.

LengthExternal (L x W)Internal (L x W)Internal floor area
10ft2.99m x 2.44m2.80m x 2.24m6.3 m²
16ft4.89m x 2.44m4.69m x 2.24m10.5 m²
20ft6.06m x 2.44m5.86m x 2.24m13.1 m²
24ft7.34m x 2.44m7.14m x 2.24m16.0 m²
External heightInternal ceiling height
2.59m2.34m
2.80m2.54m
2.96m2.70m

Typical specification

ElementSpecification
FrameCold-rolled, welded steel floor and roof frames with steel corner posts
Wall insulation60mm or 100mm mineral wool (non-combustible, class A1), or PU and PIR options
Roof insulation100mm or 140mm mineral wool or PU
GlazingDouble glazed as standard; triple glazing available
ElectricalRecessed external connection, 230V or 400V at 32A, with RCD protection
Floor22mm board with welded vinyl covering; slip resistance up to R11
TransportDelivered fully assembled or flat-packed

Typical specification shown for illustration, based on CONTAINEX CLASSIC Line modules. As a manufacturer-independent supplier, we can propose units from other manufacturers where they suit the use, site, programme or budget better. Dimensions are approximate; the confirmed specification is set out in each quotation.

Fit-out options

Each option is specified individually, so the scope reflects the requirement:

  • Floor finishes
  • Internal partitions and doors
  • Kitchen and breakroom
  • Toilets and showers
  • Broadband and data
  • Workstations and furniture
  • Video conferencing
  • Heating and lighting

Common questions

Yes. The contract can be with an individual or a company. For a company, we need the registered name and company number.

It depends on unit availability, site access, services and the fit-out. Stock units with a standard fit-out are quickest; partitioned or bespoke layouts take longer. We confirm a realistic installation date once we have the site details.

Hire suits standard units over a defined term. Where the fit-out is bespoke, or the period runs beyond about six months, buying the units and selling them on afterwards is often better value.

Yes. Units can be partitioned and fitted out with bedrooms, a kitchen and a shower room. Residential occupation may need planning permission from the local council, and establishing the necessary consents is the client’s responsibility. Our GeoConstruction division can assist with planning and building warrant applications as a separate service.

You need to own the land, or have the owner’s written consent, before any units are delivered.

Heating can be electric, or LPG or oil on rural sites without a suitable power supply. For full-time occupation over winter the heating will run for long periods, so we specify higher insulation and glazing for living units to reduce running costs, and set out the heating arrangement and expected running costs in the quotation.

Yes, by agreement. The quotation sets out who is responsible for each part of the work.

The site postcode, intended use, number of occupants, duration, photos of the site and access, the services available, and your budget.

Room for a delivery lorry and a crane or HIAB, and a suitable base where the units will sit. Ground conditions are checked at survey.

Yes. Power can be provided by generator. Water can be supplied from storage tanks, with rainwater harvesting for non-drinking use where the site suits it. On rural sites, heating can be by LPG or oil. The power, water and heating options are assessed at survey and set out in the quotation.

For purchase, payment is either in full on a pro forma invoice, or staged: 50% on order, 35% before works start and 15% on completion. New customers are normally asked to pay on pro forma. Hire terms, including the minimum hire period, are set out in the quotation.

We collect the units and reinstate the area they stood on. Collection is priced in the quotation.

Specify your facility

Describe how the space will be used and the number of occupants. We will recommend a configuration and respond within 24 hours.